HPE Aruba Networking CX 6000 48G Class4 PoE 4SFP 370W Switch
Provedení:Rack mounted 19"; Funkce:QoS (Quality of service), VLAN (virtual local area network), PoE (Power over ethernet), L2; Technologie:Gigabit Ethernet 1000Mbps; PoE budget (W):370; Počet SFP portů:4; Počet SFP portů:4; Maximální počet portů:48; PoE budget (W):370; Přenosová rychlost LAN (Mb/s):570; Maximální počet portů:48; Management:SNMP/RMON
Cena bez DPH | 24 951 Kč |
Cena s DPH | 30 190,00 Kč |
Zítra u Vás nebo na pobočce
Kategorie: | Switche |
Kód: | 709647 |
Kód výrobku: | R8N85A#ABB |
Záruka: | 24 Doživotní |
Výrobce: | Hewlett Packard Enterprise |
HPE Aruba Networking CX 6000 48G Class4 PoE 4SFP 370W Switch
Specifications |
|
Aruba 6000 48G 4SFP Switch (R8N86A) |
|
Description |
48x ports 10/100/1000BASE-T Ports
4x 1G/10G SFP ports 1x USB-C Console Port 1x USB Type-A Host port |
Power supplies |
Fixed power supply |
Fans |
Fixed fans |
Physical characteristics |
|
Dimensions |
(H) 4.39 cm (W) 44.2 cm (D) 24.74 cm (1.73" x 17.4" x 9.74") |
Configuration Weight |
3.42 kg (7.54 lbs) |
Additional Specifications |
|
CPU |
Dual Core ARM Cortex A9 @ 1016 Mhz |
Memory and Flash |
4 GB DDR3 16 GB eMMC |
Packet Buffer |
12.38MB (4.5MB Ingress/7.875MB Egress) |
Performance |
|
Model Switching Capacity |
104 Gbps |
Model Throughput Capacity |
77.3 Mpps |
Average Latency (LIFO-64- bytes packets) |
1 Gbps: 1.9 µSec |
Switched Virtual Interfaces (dual stack) |
16 |
IPv4 Host Table (ARP) |
1,024 |
IPv6 Host Table (ND) |
512 |
IPv4 Unicast Routes |
512 |
IPv6 Unicast Routes |
512 |
MAC Table Capacity |
8,192 |
IGMP Groups |
512 |
MLD Groups |
512 |
IPv4/IPv6/MAC ACL Entries (ingress) |
256 / 128 / 256 |
Aruba 6000 48G Class4 PoE 4SFP 370W Switch (R8N85A) |
Aruba 6000 48G 4SFP Switch (R8N86A) |
Aruba 6000 24G Class4 PoE 4SFP 370W Switch (R8N87A) |
|
Environment |
|||
Operating Temperature |
32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km) |
32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km) |
32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate -1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 ft (3.0 km) |
Operating Relative Humidity |
15% to 95% at 104°F (40°C) non-condensing |
15% to 95% at 104°F (40°C) non-condensing |
15% to 95% at 104°F (40°C) non-condensing |
Non-Operating |
-40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km) |
-40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km) |
-40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km) |
Non-Operating Storage Relative Humidity |
15% to 90% @ 149°F (65°C) non-condensing |
15% to 90% @ 149°F (65°C) non-condensing |
15% to 90% @ 149°F (65°C) non-condensing |
Max Operating Altitude |
10000 feet (3 km) Max |
10000 feet (3 km) Max |
10000 feet (3 km) Max |
Max Non-Operating Altitude |
15000 feet (4.6 km) Max |
15000 feet (4.6 km) Max |
15000 feet (4.6 km) Max |
Acoustic |
Sound Power, LWAd = 4.3 Bel Sound Pressure, LpAm (Bystander) = 29.8 dB |
Sound Power, LWAd = 3.6 Bel Sound Pressure, LpAm (Bystander)= 24.6 dB |
Sound Power, LWAd = 3.9 Bel Sound Pressure, LpAm (Bystander)= 24.3 dB |
Primary Airflow |
Side-to-side |
Side-to-side |
Side-to-side |
Electrical Characteristics |
|||
Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
AC Voltage |
100-127 VAC / 200-240 VAC |
100-127 VAC / 200-240 VAC |
100-127 VAC / 200-240 VAC |
Current |
4.9 A / 2.4 A |
0.8 A / 0.5 A |
4.6 A / 2.3 A |
Power Consumption (230 VAC) |
Idle: 30.6W Max Power (w/o PoE): 45W Max Power (w/ PoE): 480W |
Idle: 20.6W Max Power (w/o PoE): 44.2W |
Idle: 22.9W Max Power (w/o PoE): 32.7W Max Power (w/ PoE): 455W |
Safety |
UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014 |
UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014 |
UL 60950-1; IEC 60950-1; EN 60950-1; CAN/ CSA-C22.2 No. 60950-1; EN 60825-1 UL 62368-1 Ed. 2; IEC 62368-1 Ed. 2; EN 62368-1:2014 |
Emissions |
VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A |
VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A |
VCCI-CISPR 32, Class A; CNS 13438; ICES-003 Issue 6 Class A; FCC CFR 47 Part 15, Class A; EN 55032: 2015 +AC:2016 / CISPR-32, Class A |
Aruba 6000 48G Class4 PoE 4SFP 370W Switch (R8N85A) |
Aruba 6000 48G 4SFP Switch (R8N86A) |
Aruba 6000 24G Class4 PoE 4SFP 370W Switch (R8N87A) |
|
Lasers |
EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only) |
EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only) |
EN 60825-1:2007 / IEC 60825- 1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical Transceivers only) |
Immunity |
|||
Generic |
CISPR 24 / CISPR 35 |
CISPR 24 / CISPR 35 |
CISPR 24 / CISPR 35 |
EN |
EN 55024:2010 / EN 55035:2017 |
EN 55024:2010 / EN 55035:2017 |
EN 55024:2010 / EN 55035:2017 |
ESD |
IEC 61000-4-2 |
IEC 61000-4-2 |
IEC 61000-4-2 |
Radiated |
IEC 61000-4-3 |
IEC 61000-4-3 |
IEC 61000-4-3 |
EFT/Burst |
IEC 61000-4-4 |
IEC 61000-4-4 |
IEC 61000-4-4 |
Surge |
IEC 61000-4-5 |
IEC 61000-4-5 |
IEC 61000-4-5 |
Conducted |
IEC 61000-4-6 |
IEC 61000-4-6 |
IEC 61000-4-6 |
Power frequency magnetic field |
IEC 61000-4-8 |
IEC 61000-4-8 |
IEC 61000-4-8 |
Voltage dips and interruptions |
IEC 61000-4-11 |
IEC 61000-4-11 |
IEC 61000-4-11 |
Harmonics |
EN 61000-3-2, IEC 61000-3-2 |
EN 61000-3-2, IEC 61000-3-2 |
EN 61000-3-2, IEC 61000-3-2 |
Flicker |
EN 61000-3-3, IEC 61000-3-3 |
EN 61000-3-3, IEC 61000-3-3 |
EN 61000-3-3, IEC 61000-3-3 |
Mounting and Enclosure |
Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting |
Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting |
Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting |
Technické specifikace se mohou změnit bez předchozího upozornění. Obsah aktuálního balení se může lišit i v závislosti na datu prodeje. Obrázky mají pouze informativní charakter.